IGBT

drsstc test

Large Tesla Coil – Kaizer DRSSTC 3 – Test After 5 Years In Storage

The time is finally right for testing the large DRSSTC. A iron dummy load is used to test the primary circuit at up to 2000 A! After 4-5 long years in storage, moving around, getting kids, buying a house, move around, get more kids and then finally its time to rise and shine again! The

Large Tesla Coil – Kaizer DRSSTC 3 – Test After 5 Years In Storage Read More »

Telemechanique Altivar 58, 10kW Motor Drive Teardown

The ALTIVAR 58 (ATV58) family of adjustable frequency AC drive controllers is used for controlling three-phase asynchronous motors. This controller in from the range of: 1–75 hp (0.75–55 kW) constant torque (100 hp variable torque), 400/460 V, three-phase input. In this teardown, I am giving you an overview of how its built, non-destructively as the

Telemechanique Altivar 58, 10kW Motor Drive Teardown Read More »

Teardown of a 5 kVA / 4 kW Eaton EX5RT UPS System

Teardown of a 5 kVA / 4 kW Eaton EX5RT UPS System

Teardown of a Eaton EX RT 5 kVA UPS model. The topology is a on-line double conversion with PFC (Power Factor Correction). The system is rated for a active power output of 5 kVA / 4 kW. I have also other teardown videos of 20 kVA UPS, 30 kVA UPS or even up to 60

Teardown of a 5 kVA / 4 kW Eaton EX5RT UPS System Read More »

Salvaged IGBT Bricks From Power Electronics – Isolation, Day 18

Over the years I have collected a great deal of salvaged IGBT bricks from the different power electronics I have taken apart. It have primarily kept 50+ Ampere rated bricks, single or half-bridge modules and 3 phase modules without built-in protection. It mostly comes from UPS, motor drives, welders or x-ray generators.

Salvaged IGBT Bricks From Power Electronics – Isolation, Day 18 Read More »

70 kV / 65 kW X-Ray System, Transformer and Inverter – Isolation, Day 12

I give an overview of a 65kW X-ray generator system for a 70 kV X-ray transformer. The full-bridge of 400A 1200V IGBT bricks makes for a powerful inverter to drive the ferrite cored high voltage transformer.

70 kV / 65 kW X-Ray System, Transformer and Inverter – Isolation, Day 12 Read More »

ABB TRIO 20 kW Solar Inverter – Unboxing and Teardown

Teardown of a large solar inverter. The ABB TRIO 20 kW inverter is a three-phased inverter built around many TO-247 IGBT & Schottky diodes. Three-phase string inverter, 20000Wac, 2 MPPT, 4 DC inputs for each MPPT, RS485 communication interface, IP65 (NEMA4x) environmental protection degree, integrated DC and AC disconnect switch, DC and AC surge arrester

ABB TRIO 20 kW Solar Inverter – Unboxing and Teardown Read More »

ESAB Power TIG 200 Welder Teardown

A teardown of a ESAB Power TIG 200 welder. It is also known as the ESAB LTR200. In this video I do a run down of the current paths in the system and I show which parts I kept. I have also done teardown videos on other welders or plasma cutters, so check those out

ESAB Power TIG 200 Welder Teardown Read More »